Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-367CLSFY-PT (Call Classifier Port)
3
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. There are two possible alarm levels for this error type: major alarm and
minor alarm. A major alarm is raised if the total number of call classifier
ports currently in-service is less than or equal to 1/2 of the administered
threshold number. Otherwise, a minor alarm is raised. In either case, run
the short test sequence against the port and follow the error code
procedures for the individual tests.
The threshold number of call classifier ports for service is administered
using the
change system-parameters maintenance
command.
b. The call classifier port lost its translation. Testing the call classifier port is
sufficient to reload its translation. If testing the call classifier port does not
clear the error, then the call classifier circuit pack containing the defective
call classifier port should be replaced.
c. This error indicates the call classifier port is having problems detecting
system tones (DTMF, etc.) or detecting and generating necessary R2-MFC
tones. This error should accompany some percentage of failed calls. If this
error type is persistently logged, then the call classifier circuit pack
containing the defective call classifier port should be replaced.
Table 3-162. Call Classifier Port (CLSFY-PT) Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1 any Tone Detector
Audit/Update Test
(#43)
MAJOR/
MINOR (a)
ON test port PCSSpp r 2
18 Port has been
busied out by
system technician
WARNING OFF release port PCSSpp
257 (b) 17666 Test (#43) MAJOR/
MINOR (a)
ON test port PCSSpp r 3
513 (c) any Tone Detection
Verification Test
(#42)
MAJOR/
MINOR (a)
ON test port PCSSpp r 3
Continued on next page