Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-42Restoring Power
1
Restoring Power
The procedures you need to restore power depend on the system configuration.
Before performing these activities, refer to the appropriate procedure. Restore
power as follows:
1. Plug in power cords in port cabinets first.
2. Make sure that the translation card is properly inserted into the slot.
3. The system now goes through the rebooting process.The translations are
loaded from the translation card, and rebooting takes about 3 minutes.
4. When system power is restored, the appropriate display is shown on the
administration terminal.
The display is the same as a
reset system 4
.
5. Reset the time using the
set time
command. Use
display time
command
to verify.
Power Up the AUDIX System
If the AUDIX was removed from the cabinet:
1. Re-install the AUDIX and allow it to boot up automatically.
2. Check fro SUCIX System errors.
If the AUDIX remained in the cabinet, but power was removed from the cabinet:
1. Power up the cabinet. The AUDIX reboots automatically.
2. Check fro AUDIX System errors.
If the AUDIX remained in the cabinet and the cabinet
was not
powered down:
1. At the AUDIX console, hold the
crtl key down and enter
cc
.
2. Enter
5
at the prompt. In about 2 minuted the AUDIX boots up.
3. When the system initialization is complete, log in as
craft
.
4. Check for AUDIX System errors.
Replacing the Power Supply
1. Pull on the latch for the 650A Power Supply.
2. Replace the power supply and secure the latch.