DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-816MET-LINE (MET Line)
3
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. This indicates that the EPF has been turned off due to the overcurrent
condition at the voice terminal. Check for defective wiring, check for a
damaged jack, and make sure the voice terminal is a MET set. Once the
problem has been resolved, the alarm is retired due to the passing of time.
e. The particular station audit that causes this error type to be produced is
the EPF inquiry audit. If the EPF inquiry receives an "epf-no-load" message
a certain number of times, this error occurs and, if the EPF inquiry receives
an "epf-on-ok" or an "epf-off-ok" message, it contributes to the resolution of
this alarm.
This indicates that the voice terminal has probably been disconnected or
that there is a problem in the wiring to the terminal. Make sure that the
voice terminal is connected or check for defective wiring to the voice
terminal.
f. This indicates that something is wrong with the link to the voice terminal.
An in-line maintenance error has generated an off-board Minor alarm.
Ignore if there are no complaints. Otherwise, verify that the voice terminal
is connected, check for defective wiring, check for a defective voice
terminal, and move voice terminal closer to the switch (in terms of feet of
wire from the jack to the switch). If the problem still exists, replace the
circuit pack.
g. This indicates that the station went off-hook while it was in the
ready-for-service state. Use the
status system
command to determine
the state of the station. The off-hook should have moved the station to
ready-for-service. No action is necessary.
h. This is the code that is generated when the link between the circuit pack
and the voice terminal is successfully reset. No action is necessary.
i. An uplink message being logged that the EPF is one with no load on it. No
action is necessary.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
Port
Diagnostic Test,
for example, you may also clear errors generated from other
tests in the testing sequence.