DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-779MAPD-BD (MAPD Interface Circuit Pack TN802)
3
257 65535 Control Channel Loop
Test (#52)
MIN ON test board UUCSS l r 20
257 (f) Any None
513 (g) Any MIN/
WRN
3
ON
514 (h) 46086 MIN/
WRN
3
ON
769 (i) 46085 MIN/
WRN
3
ON
770 (j) 46096 MIN/
WRN
3
ON
1025 (d) 4363 NPE Audit Test (#50)
1281 Any Loss of Signal Alarm
Inquiry Test (#138)
MIN/
WRN
3
OFF test board UUCSS
1537 (k) 46082 MIN/
WRN
3
ON
1538 (l) Any MIN/
WRN
3
ON
1793 Any Blue Alarm Inquiry Test
(#139)
MAJ/
MIN/
WRN
4
OFF test board UUCSS
2049 Any Red Alarm Inquiry Test
(#140)
MIN/WR
N
3
OFF test board UUCSS
2305 Any Yellow Alarm Inquiry Test
(#141)
MIN/
WRN
3
OFF test board UUCSS
2306 Any Yellow Alarm Inquiry Test
(#141)
MIN/
WRN
3
OFF test Board UUCSS
2561 Any Major Alarm Inquiry Test
(#142)
MIN/
WRN
3
OFF test board UUCSS
2817 Minor Alarm Inquiry Test
(#143)
MIN/
WRN
3
OFF test board UUCSS
3073 to
3160
(m)
Any Slip Alarm Inquiry Test
(#144)
MIN/
WRN
3
OFF test board UUCSS r 6
3330 (n) 46083 MIN/
WRN
3
ON
Table 3-326. MAPD (TN802) Error Log entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page