Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-120list measurements clan ppp
2
High Cyclic Redundancy Check (CRC)—detects and corrects errors on
every frame) errors could suggest that the connection may be “noisy”
The 24-hour history gives the ability to look back at these measures if the trouble
cleared.
Data is retrieved for 15-minute intervals for 24 hours for CRC, Invalid Frame and
Chap Failures for PPP connections. If the data cannot be retrieved for the 15
minute interval,
N/A
displays in the field. The delta (the change from the last
inquiry) and the total are provided for each error count. After the occurrence of
an “N/A,” the delta equals the total.
Output
The following example shows the output from the
list measurements clan ppp
command.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
list
measurements
clan ppp
UUCCSS
pp
print
schedule
Link identifier (primary
or secondary)
Port Address
Report sent to printer
Command is validated
and then a scheduling
form displays to
schedule execution of
the command. The
command is then
placed in the
command queue and
is executed at the
specified time. The
information displayed
by the command is
sent to the system
printer instead of the
screen.
1
Examples:
list measurements
clan ppp
list measurements
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
customer
Primary