DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1052TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
3
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. The far-end has reported that this channel is not administered. The trunks
are placed in the out-of-service state.
b. The Signaling link is down. See the following Aux Data explanation:
— Aux data 8 indicates the Signaling Link is down.
— Aux data 9 indicates the Port is out of service.
c. The Service State Audit failed. The test will be run every 15 minutes until it
passes.
d. Unexpected Restart message; this error causes no action and is logged
only.
e. B-Channel Rejection Event; this action causes the Service State Audit, the
Call State Audit, and the Test Call Audit to be executed.
Table 3-467. TBRI-TRK Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test Port UCSSPP sh r 1
513 (a) Service State Audit
(Test #256)
WARNING OFF
1793 (b) 8, 9 WARNING OFF
3073 (c) Service State Audit
(Test #256)
3585 (d)
3841 (e) WARNING OFF
Continued on next page