Maintenance Objects
3-1149TRANS-ID (Translation-ID)
3
Processor replacement procedure screens
Screen 3-5. Maintenance-related system parameters (change system-parameters
maintenance)
7. Lucent services resets
the translation ID
reset translation-id Lucent Services executes the
command. Distributors or
third-party vendors must also
contact Lucent Services.
NOTE:
The system message,
Cannot reset
translation-ID
without standby
SPE being
accessible, means
that both processors
must be sane and
operational.
8. Switch to the A-side reset system
interchange
Switches SPE control to the
active, or A-side.
9.
Repeat for High and
Critical Reliability
systems
Go back to Steps #3 through
#8, this time performing the
steps on the A-side.
Table 3-505. Processor circuit pack replacement procedure — Continued
Step Description Command Procedure
Continued on next page
change system-parameters maintenance Page 1 of 2 SPE B
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
Product Identification: 1501137003
First OSS Telephone Number: Abbrev Alarm Report? y
Second OSS Telephone Number: Abbrev Alarm Report? n
Alarm Origination to OSS Numbers: neither
Cleared Alarm Notification? n Suspension Threshold: 5
Restart Notification? n
Test Remote Access Port? n
CPE Alarm Activation Level: none
Customer Access to INADS Port? n
Repeat Dial Interval (mins): 7
SCHEDULED MAINTENANCE
Start Time: 01 : 00 Stop Time: 01 : 01
Daily Maintenance: daily Save Translation: no
Control Channel Interchange: daily System Clocks Interchange: daily
SPE Interchange: daily