DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-300BRI-SET, ASAI-ADJ, BRI-DAT
3
42 Switch
Equipment
Congestion
Switch takes control to limit received traffic. For BRI
endpoints: This cause value is not logged. For ASAI
or Lucent Adjuncts:
1. See CallVisor protocol reference manual.
Service or Option
Not Available
50 Requested
Facility Not
Subscribed
Requested facility is implemented, but not
administered. Potential administration problem with
endpoint or adjunct. For BRI endpoints:
1. Verify the switch administration of endpoint
using either the display station or display
data-module commands.
2. If Step 1 does not resolve the problem, refer to
the endpoint’s service manual and verify
administration on the endpoint.
For ASAI adjuncts:
1. Display the Customer Optional Features Form
(administration screen) on the switch to
determine which ASAI capabilities are turned
on in the switch.
2. Verify that the adjunct is administered to
support the identical capabilities as the switch.
If there is a mismatch in the administered
capabilities, then readminister the switch and/or
the adjunct to establish a consistent set of
desired capabilities on both the switch and the
adjunct.
For Lucent adjuncts:
1. Display the Customer Optional Features Form
(administration screen) on the switch to
determine if the adjunct is set enabled on in the
switch.
2. If error type 2567 or 2568, verify the adjunct
version, and readminister if needed.
58 Bearer Capability
Not Presently
Available
Requested bearer capability is implemented, but
not administered. No B-channel administered. See
recommendation 50 above.
Service or Option
Not Implemented
Table 3-131. ISDN-BRI Cause Values — Continued
Code Explanation Recommendation
Continued on next page