DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-53ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
3
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. These are in-line errors and can only be resolved over time.
■ 40960—indicates that too many simultaneous incoming ringing
attempts were made on this board. Only four ports on a board may
be ringing simultaneously. A fifth incoming call will cause an inline
error from the board.
Table 3-22. 8-Port Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40960
40975
40977
None
15 (b) Any Audits and Updates
Test (#36)
18 0 busyout station
<extension>
WRN OFF release station <extension>
130 (c) None WRN ON test port PCSSpp sh
257 (d) Station Present Test
(#48)
WRN OFF test port PCSSpp sh r 3
513 Battery Feed Test
(#35)
MIN/
WRN
2
2. Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used
in the set options command.
ON test port PCSSpp sh r 2
769 (e) Loop Around and
Conference Test(#47)
test port PCSSpp l r 3
1025 NPE Crosstalk Test
(#6)
MIN/
WRN
2
ON test port PCSSpp l r 3
1281 (f)
1793 (f)