DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-828MET-LINE (MET Line)
3
MET Line Station Audits Test (#61)
This is a series of three tests that are classified as audits. These audits abort if
attempted on an out-of-service station. The tests are as follows:
Switchhook Audit—This is an update of the SPE records according to the
circuit packs’ records.
Bad Scan Inquiry—A message is sent uplink that contains a count that is
generated due to certain events relating to the link conditions. This is an
indication of data transmission problems between the MET Line circuit
pack and the voice terminal.
EPF Inquiry—The status of the EPF is sent uplink. Possible conditions are:
EPF-on-ok, EPF-off, EPF-no-load, and EPF-on-overcurrent.
Although this test will never actually return a fail result (except for the internal
system error), it is possible that it will enter error types 257 (over current) or 513
(open circuit) into the error log. To determine if there are any problems that do not
show up in the test result, look for these error types in the error log. If these errors
appear in the error log or if user complaints still exist, investigate by using other
circuit pack tests and by examining the station, the wiring, and the connections.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
check to ensure that there is a valid board inserted.
Table 3-358. TEST #60 MET Line Station Lamp Updates Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page