DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-69Troubleshooting Features
1
In this method, four commands are used to start, stop, query, and list an outgoing
ISDN-PRI test call. These commands are as follows:
clear isdn-testcall <grp>/<mbr>
(stop)
list isdn-testcall
(list)
status isdn-testcall <grp>/<mbr>
(query)
test isdn-testcall <grp>/<mbr> [minutes]
(start)
NOTE:
Before placing an outgoing ISDN-PRI test call, verify that the FAC on the
System Features Form has been administered as well as the Far End Test
Line No and TestCall Bearer Capability Class (BCC) on the Trunk Group
Administration Form. Furthermore, if the ISDN-PRI trunk is of the “cbc” (call
by call) service type, then the
Testcall Service
field on Trunk Group
Administration Form must have been administered also.
To initiate an outgoing ISDN-PRI test call in the asynchronous method, issue the
following command:
test isdn-testcall <grp>/<mbr> [minutes]
This command enables you to specify a specific the trunk on which to originate
the ISDN-PRI test call.
NOTE:
The optional qualifier can also be used that specifies in minutes the
duration of the test call. If no duration is specified, the default duration is
used which is 8.4 or 9.6 seconds. The qualifier “minutes” accepts the
numeric values one through 120 (that is, two hours = 120 minutes).
Figure 1-20
shows a typical response to the
test isdn-testcall
command:
Figure 1-20. Typical Response to Test ISDN-Testcall Command
test isdn-testcall
Port Maintenance Name Test Number Test Result Error Code
1B1501 ISDN-TRK 258 PASS