DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-411CO-TRK (CO Trunk)
3
Table 3-178. TEST #844-848 Transmission Test
Error
Code
Te s t
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use display port PCSSpp to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port unavailable for this test. You must wait until the
port is idle before retesting.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1001 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate timeslots for the test. The system may be
under heavy traffic conditions or it may have timeslots out of service due to
TDM bus errors. Refer to TDM Bus Maintenance to diagnose any active
TDM bus errors.
1. If system has no TDM bus errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
1004 ABORT The port has been seized by a user for a valid call. Use status trunk to
determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1005 ABORT Trunk has been administered as incoming-only; transmission tests can
only be run on outgoing trunks.
1115 ABORT The near end test line could not be allocated.
1. Verify that the TN798 circuit pack’s port 1 is administered and in
service with the status port command.
2. Retry the command at 1-minute intervals a maximum of 5 times.
1900 ABORT The test completion message was not received from the TN798 circuit
pack.
1. Test the TN798 circuit pack.
1901 ABORT This error occurs when the TN798 circuit pack uplinks a message that is
not the proper response for this test. The anticipated uplink messages are
seize, ring or answer.
1. Verify that the Trunk is administered properly.
Continued on next page