Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-302status sys-link
2
Output
The following example shows the output for the
status synchronization
command.
Field descriptions
status sys-link
This command displays status data for a specified system link. The report
includes the type and operational state of the link, the associated processor
channel (if any), active alarms and path status, and a list of all hardware
components making up the link’s path.
Stratum Level
Synchronization stratum level (3 or 4)
Maintenance
Name:
Either
TONE-BD
,
DS1-BD
, or
STRAT-3
.
Physical
Location
Board location of the selected DS1 or tone-clock circuit pack
(cabinet-carrier-slot for a DS1; cabinet-carrier for a tone-clock)
Switching
Capability
Whether the on-line reference for synchronization can be switched
(
Enabled
or
Disabled
)
Excessive
Reference
Switching
High-level description of how many times the synchronization
reference has been switched. If excessive reference switching is
taking place (sync error 1793 is at threshold), this field displays
Yes
; otherwise
No
displays.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status sys-link
location
Port location:
PCSSpp
Example:
status sys-link 1b0201
init
inads
craft
none none
status synchronization
SYNCHRONIZATION STATUS
Stratum Level:4
Maintenance Name: TONE-BD Physical Location: 01A
Switching Capability: Enabled
Excessive Reference Switching: No