DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-98ANN-BD (Announcement Circuit Pack)
3
b. Error Type 14 Whenever the Announcement Checksum Test (#209)
fails, this error is logged. The Aux Data indicates the number of the first
defective announcement found. This number corresponds to the
announcement numbers on the announcement form. The extension
relating to the announcement can be determined by the
display
announcement
command. This error only appears in the Error Log in
conjunction with Error Type 2817. Follow the procedures for Error Type
2817 to troubleshoot Error Type 14.
c. Error Type 23
The circuit pack has been logically administered but not
physically installed. The alarm is cleared when the circuit pack is installed.
d. Error Type 125
A wrong circuit pack is inserted in the slot where this
circuit pack is logically administered. To resolve this problem, either
remove the wrong circuit pack and insert the logically administered circuit
pack OR use the
change circuit-pack
command to readminister this slot
to match the circuit pack inserted.
e. Error Type 217 and 267
Indicate that there is more than one TN750
Announcement circuit pack inserted in the system. Remove the alarmed
circuit pack.
f. Error Type 257
This error indicates transient communication problems
with this circuit pack. This error is not service-affecting and no action is
required.
g. Error Type 513
This error, when reported with Aux Data in the range of
4352 to 4358, indicates the circuit pack has reported a hardware failure on
the circuit pack. The circuit pack should be replaced.
!
WARNING:
Replacing the circuit pack results in loss of integrated
announcements (TN750/B only). See ‘‘General Notes’’
near the
beginning of this Maintenance procedure.
h. Error Type 1025This error is not service-affecting and no action is
required.
i. Error Type 1281
The SP found a fault in the speech main memory (SMM)
(that is, it found one or more faulty memory locations). Whenever this error
is logged, error 2817 is also logged [see Note (j)], which causes the
maintenance system to run the Announcement Checksum Test (#209) to
determine if the bad memory location was being used by an
announcement.
j. Error Type 1538
The hyperactive circuit pack is out-of-service and may
exhibit one or more of the following symptoms:
1. The tests run on the ports of this circuit pack are returning with a
NO-BOARD.
2. A busyout/release of the circuit pack has no effect on test results.