Maintenance Commands
2-28change system-parameters maintenance
2
CPE Alarm
Activation
Level
Indicates the minimum level (Major, Minor or Warning) to activate
Customer-Provided Equipment (CPE) alarm. If the level is
none
, the
CPE does not activate for any alarm.
NOTE:
When the switch goes into Emergency Transfer, the CPE alarm
activates regardless of the CPE Alarm Activation Level setting.
Packet Bus
Activated
If this field is set to
yes
, maintenance software assumes that a
Packet Control circuit pack is installed. If packet endpoints (for
example, ASAI, and/or BRI) are administered, and maintenance
testing runs on both the Packet Control circuit pack and Packet Bus,
set this field to
yes
after a packet control circuit pack is installed. If a
Packet Control circuit pack is not installed in the system, a major
alarm is raised against the PKT-CTRL MO.
Change this field to
no
if no packet endpoints are administered, to
ensure that no packet endpoints can be administered if the packet
bus deactivated.
If a Packet Control circuit pack is not installed, then this field should
be set to
no
(the only exception is system translations that do not
have all required hardware).
Customer Access
to INADS Port
To prevent customer login ID access to system administration and
maintenance interface control, set this field to
no
. Lucent
Technologies services has sole access to this field.
Repeat Dial
Interval (MMS)
Number of minutes that the system must wait before attempting
another call origination to an OSS. Lack of a far-end
acknowledgment triggers the timer.
Scheduled Maintenance
Start Time
Hour and minute (24-hour notation) when daily scheduled maintenance
starts
Stop Time
The hour and minute when scheduled daily maintenance ceases. If any
daily maintenance operations are not completed by this time, the
system notes its stopped sequence location and includes those
operations during the next scheduled daily maintenance.
Daily
Maintenance
This display-only field lists the standard test series run by maintenance
software during daily maintenance.
Save
Translation
Indicates days that translation data in memory automatically saves to
the Mass Storage System disk and/or tape devices during scheduled
maintenance. The operation saves to disk, then completes a backup to
tape. Translation data saves to both SPEs, if systems have duplicated
SPEs. (daily, days of the week, or no - prevents automatic saves)