DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-212V-PWR (12 Volt Power Supply)
3
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following table. By clearing
error codes associated with the
12 Volt Power Supply Test
for example, you may
also clear errors generated from other tests in the testing sequence. The 12 Volt
Power Supply Test can be initiated through either the
test card-mem
command
or the
test network-control
command.
Table 3-1. 12 Volt Power Supply Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board
Test to Clear
Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test card-mem
1
2
2. Software cannot turn on the 12 volt power supply to provide 12 volt power to the flash memory or to
the translation card.
Any 12 Volt Power Supply Test
(#701)
MINOR ON test card-mem
257
3
3. Software can turn on the 12 volt power supply, and 12 volt power is available. However, the software
cannot turn the power supply off after operations are completed. The 12 volt power remains on. This
error does not affect the normal operations involved in accessing the memory or the translation
card.
Any 12 Volt Power Supply Test
(#701)
WARNING ON test card-mem
Table 3-2. System Technician-Demanded Tests: 12-V PWR
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence D/ND
1
12 Volt Power Supply Test (#701) X X ND
Memory Card Insertion Test (#695)
2
XX ND
Memory Card Format and Read Test (#696)
2
XX ND
Memory Card Match Test (#697)
2
XX ND
Memory Card Write-Protected Test (#698)
2
XX ND
Continued on next page