DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-46System Backup
1
7. Remove the backup translation card and insert the original translation
card.
8. Label the backup translation card with the date and time it was updated. A
special notation on the card clearly distinguishes it from other cards.
9. Store the backup translation card in a secure place.
Translation Card Errors
Translation card-related failures may occur for two reasons: the card is at fault, or
the Processor circuit pack is at fault. The following is a list of the error messages
and recommended responses to each.
1.
Cannot access file storage area
—Implies that the wrong
translation card may be installed.
Response:
Check to see which translation card is installed. If the correct
one is installed, test it by using the
test card-mem
command.
2.
Cannot turn on 12 volt power supply
—Implies that something
may be wrong with the Processor circuit pack that contains the power
supply.
Response:
Test the 12-volt power supply by entering the
test card-mem
command from the terminal. Executing this command causes the system
to run Test 701 (12 Volt Power Supply Test). If the power supply test fails,
replace the Processor circuit pack. Then repeat whichever command
failed.
3.
Invalid directory on Card-Mem
— The translation card needs
refreshing. Run
test card-mem
and be sure all tests pass.
4.
Card-Mem is unusable
— Something is wrong with the translation
card. Replace the translation card.
5.
Could not write to Card-Mem
— Something is wrong with the
translation card. Test the translation card.
6.
Request is incompatible with currently running
operations
— The storage system is in use. Try again later.
7.
Card-Mem is not inserted in the system
— Insert the translation
card.
8.
Cannot access file; wrong type of Card-Mem is inserted
— The correct translation card for the desired operation has not been
inserted. Load the appropriate translation card.
9.
File size exceeded
— There is no more file space. Call your Lucent
Technologies representative.
10.
Upgrade Memory Card inserted
— The system upgrade translation
card may have been inserted instead of the translations card. Insert the
translation card.