Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1279WAE-PORT (Wideband Access Endpoint Port)
3
DEFINITY PBX) via the dedicated fractional T-1. All Wideband Access Endpoint
functionality and operation is identical on both line-side and network facilities.
However, because maintenance capabilities are limited to the Wideband Access
Endpoint interface, and because faults can occur end-to-end, troubleshooting
procedures based on an end-to-end view of the network is required.
Wideband Access Endpoint Port maintenance provides a strategy for
maintaining a Wideband Access Endpoint Port via a port on the Universal DS1
interface circuit pack hardware. The maintenance strategy involves logging
Wideband Access Endpoint Port hardware errors, running tests for port
initialization, periodic and scheduled maintenance, system
technician-demanded tests, and alarm escalation and resolution. Two different
port service states are specified in the Wideband Access Endpoint Port
maintenance. These states include
out-of-service
, where the port is in a
deactivated state and cannot be used for calls, and
in-service
, where the port is
in an activated state and can be used for calls. If the Universal DS1 Interface
circuit pack (TN464C) is out-of-service, all ports on the Universal DS1 Interface
circuit pack (TN464C) are placed into the out-of-service state.
Hardware Error Log Entries and Test to Clear
Valu es
Wideband Access Endpoint Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test access-endpoint
<extension> sh r 1
18 (a) 0 busyout
access-endpoint
WARNING OFF release access-endpoint
<extension>
130 (b) None WARNING ON test access-endpoint
<extension>
1281 (c) Conference Circuit
(Test #7)
MINOR ON test access-endpoint
<extension> l r 4
1537 (d) NPE Crosstalk Test
(#6)
MINOR ON test access-endpoint
<extension> l r 3
1793 (e) None test board PCSS long
3840 (f) Any Port Audit and
Update (Test #36)