DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1258VC-BD
3
Error Log Entries and Test to Clear Values
Notes:
a. The circuit pack stopped functioning or it was removed from the system.
This alarm is logged approximately 11 minutes after the circuit pack is
removed and/or the SAKI Sanity Test (#53) fails.
To resolve this error, insert a circuit pack in the same slot as the error
indicates, if the circuit pack is not already in the system. Or, if the circuit
pack is in the system and the red LED is on, then follow instructions for
Red alarms.
!
CAUTION:
If the TN788 Voice Conditioner Circuit Pack (VC-BD) is not Vintage 2
or later, it must be replaced.
b. This circuit pack is busied out by the
busyout board PCSS
command.
Table 3-537. VC-BD Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If all tests pass, run the long test sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test board PCSS sh r 1
1 (a) Any None MIN ON
18 (b) 0 busyout board PCSS WNG OFF release board PCSS
257 (c) Any Control Channel Loop
Test (#52)
MIN ON test board PCSS r 20
513 (d) 4352 to
4357
769 (e) 4358
1025 (f) 4363 NPE Audit Test (#50)
1281 (g) Any SAKI Sanity Test (#53) MAJ ON
1293 to
1294 (h)
46088
to
46096
SAKI Sanity Test (#53) MIN ON See note (g)
1538 (i) 46082 MIN ON
Continued on next page