DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1054TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
3
Service State Audit (#256)
This test is nondestructive. This test performs a service state audit on an ISDN
B-Channel. The test passes if Call Processing informs Maintenance that the
Restart message was transmitted successfully, or if the B-Channel was busy and
could not send the message.
The test fails if the board is not inserted or translated properly, or if a reply is not
received within a certain amount of time.
The test aborts if the signaling link is disconnected, if a message is already
outstanding, or if the necessary resources could not be allocated. Maintenance
will take no action if the test aborts.
To investigate the service state of the TN2185 ISDN Trunk-Side BRI Channel,
issue the
status trunk trunk-group/trunk-member
command.
9 FAIL The port is out of service.
1. Return the port too an in service state.
PASS The signaling link is connected and operating normally.
Table 3-469. TEST #256 Service State Audit Test
Error
Code
Te st
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available. The port may
be on a valid call. Use status trunk to determine when the trunk is
available for testing.
1. Check the results of Test #1251 (Signaling Link State Check).
1018 ABORT The test is disabled.
1. Enable maintenance by entering y in the
Maintenance Tests?
field on page 2 of the change trunk-group form.
1113 ABORT The signaling link has failed, so the system cannot send any messages on
behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State Test ).
Continued on next page
Table 3-468. TEST #1251 Signaling Link State Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page