Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-10How to use the Maintenance book
1
17. Perform both steps in the Description/Recommendation column.
18. Test the port (
test port 01C1008 long
and press
Enter.) again after all of
the recommendations are exhausted.
19. If all tests pass, wait approximately 3-5 minutes for the Alarm and Error
logs to clear.
20. Type display alarms and press
Enter twice.
21. Check that the DID-TRK alarm does not appear in the log.
Field descriptions
Table 1-3. TEST #35 Port Diagnostic Test
Error
Code
Test
Result Description/Recommendation
61472 FAIL Battery feed test failed. A problem with the incoming CO line was
detected.
1. Check the incoming CO line for proper operation. If warranted, refer
the problem to the CO.
2. If the CO line checks out Ok, the failure must be on the DID port.
Replace the circuit pack.
Continued on next page
Error type
Enter error type, or blank
Error List
active-alarms, errors, or cleared-errors
Interval
h(our), d(ay), w(eek), m(onth), a(ll)
From:/To:
Specify time interval by date and time
Cabinet
Enter cabinet number (1 - 44)
Port Network
Enter port network number (1 - 44)
Board Number
Enter 5-character board number in
UUCSS
format:
cabinet (1-44), carrier (A-E), slot (0-20)
Port
Enter 7-character port address in
UUCSSss
format:
cabinet (1-44), carrier (A-E), slot (0-20), circuit
(01-31)
Category
Enter category name (choose 1 from the list below:
adm-conn announce bri/asai cdr data-mod
detector dup-spe environ exp-intf ext-dev
generatr inads-link infc maint mass-st