DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-832MIS (Management Information System)
3
MIS (Management Information
System)
The Management Information System (MIS)/Call Management System (CMS) MO
is used only for administering MIS translations, such as trunks and stations.
There are no hardware failures associated with this MO.
NOTE:
To diagnose MIS link hardware errors and alarms, see PKT-INT (Packet
Interface).
The MIS/CMS is an adjunct processor that collects ACD data sent from the
system. To change MIS translations, a system administrator must first enter a
busyout mis
command at the terminal. When the MIS is busied out, the system
stops sending ACD data to the MIS, and a Warning alarm is raised. When
finished, a
release mis
command should be entered at the terminal. This clears
the Warning alarm and allows the switch to send ACD data to the MIS.
Error Log Entries and Test to Clear Values
Note:
a. When the
busyout MIS
command is issued, no data is sent to the
MIS/CMS regardless of the link state. To allow data to be sent to MIS/CMS,
a
release mis
command must be issued from the terminal.
MO Name (in
Alarm Log
Alarm
Level Initial Command to Run Full Name of MO
MIS WRN release mis Management Information System
Error Type Aux Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any release mis
18(a) 0 busyout mis WARNING ON release mis