DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-337test environment
2
Output
The following example shows the output for the
test external-device-alarm all
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field definitions
test environment
This command performs hardware diagnostic tests of the environment
monitoring and control, and emergency transfer functions of the Processor Port
Network (PPN) cabinet. Circuit packs involved are the Processor (PPN simplex
systems) and the Duplication Interface circuit packs. The tone/clock circuit pack
is involved in tests of the ring generator.
There are 8 Maintenance Objects involved in this testing:
1. CABINET tests air flow and temperature
2. EMG-XFER tests emergency transfer status
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance Name
The name of the maintenance object
Alt. Name
The alternate means of identifying the maintenance object, in
this case, the administered (descriptive) name of the external
device alarm.
Test No
The test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, or Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of the codes by test number for each
MO.
test eda-external-device-alarm all
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01major EXT-DEV UPS1 120 PASS
01minor EXT-DEV UPS1 120 PASS
01c1201 EXT-DEV UPS1 120 PASS
01c1202 EXT-DEV Audix1 120 PASS
Command successfully completed