1-7How to use the Maintenance book
1
Alarms are further classified as:
On-board problems originate in the circuitry on the alarmed circuit pack.
Off-board problems originate in a process or component that is external to
the circuit pack.
To clear system alarms using the appropriate maintenance book:
1. Type
display alarms
and press
Enter.
2. A query screen displays next (Screen 1-1
), asking you if you want to see
all alarms or if you want to restrict the list to certain kinds of errors.
Screen 1-1. Alarm Report query screen
a. The report can be restricted by typing either
y
(yes) or
n
(no) in
these fields (shown above in bold):
Active
Major
Minor
Warning
!
CAUTION:
If you choose
n
for major alarms and
y
for minor and warning
alarms, you will not see the macro-level information that you
may need to determine what is wrong with the system.
b. The Cabinet, Port Network Board Number, Port and Category fields
are described in the
‘‘Field descriptions’’
section.
3. After you have made your choices to tailor the report, press
Enter.
4. The alarm log displays.
ALARM REPORT
The following options control which alarms will be displayed.
ALARM TYPES
Active? y Resolved? n
Major? y Minor? y Warning? y
REPORT PERIOD
Interval: m From: / / : To: / / :
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet:
Port Network:
Board Number:
Port:
Category: