DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-766MAPD-BD (MAPD Interface Circuit Pack TN802)
3
Backing up to the PCMCIA disk
Table 3-321 details how to back up administration data for the IP trunk
application to and restored from the local PCMCIA disk and the Ethernet port.
Before backing up, be sure to shut down the application running on the circuit
pack, following the procedures in the ‘‘Shutting down NT on the TN802’’
section.
DCS Know limitations:
Auto Callback
Coordinate specific administration
and between the IP trunk and
DEFINITY ECS for any DCS
functionality. Some limitations on
routing flexibility may apply.
ISDN IP trunking has no signalling
capability.
ISDN not supported. This includes:
10-digit number display
QSIG
Path replacement
Voice mail Calls that have terminated at
one location and then cover
to a second site for voice
mail coverage can have
voice quality degradation.
Centralized voice mail through an
IP network is not recommended.
Table 3-321. Backing up TN802 administration data
Step Description Comments
1. Busyout circuit pack At the DEFINITY ECS terminal type busyout
board UUCSS (the address of the TN802 circuit
pack) and press Enter.
2. Backup administration
TN802 to disk
At the Windows NT desktop, double-click on the
IP Trunk Backup Restore icon.
The IP Trunk Backup/Restore Utility screen
appears.
Continued on next page
Table 3-320. DEFINITY ECS IP trunk feature/performance limitations — Continued
Feature/
Performance Description Recommendation
Continued on next page