DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1091TIE-DS1 (DS1 Tie Trunk)
3
Hardware Error Log Entries and Test to Clear
Valu es
Table 3-484. DS1 Tie Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0 Any Any Any test trunk <grp>/<mbr> sh
r 1>
1 (a) 57476
57477
57485
57487
15 (b) Any Port Audit and
Update Test (#36)
18 (c) 0 busyout trunk
<grp>/<mbr>
WARNING OFF release trunk
<grp>/<mbr>
130 (d) None WARNING ON test trunk <grp>/<mbr>
257 (e) 57473
57474
513(f) 57392 DS1 Tie Trunk
Seizure Test (#136)
MIN/MAJ
2
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are
out of service, then the alarm will be upgraded to a MAJOR alarm.
769(g) 57393 DS1 Tie Trunk
Seizure Test (#136)
MIN/MAJ
2
1025 DS1 Tie Trunk
Seizure (Test #136)
MAJ/MIN/
WRN
3
3. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set
options command. If the MINOR alarm is not downgraded by the set options values, the MINOR alarm
is upgraded to a MAJOR alarm if 75 percent of the trunks in this trunk group are alarmed.
OFF test trunk <grp>/<mbr> r
2
1281 Conference Circuit
(Test #7)
MAJ/MIN/
WRN
3
ON test trunk <grp>/<mbr> l r
4
1537 NPE Crosstalk Test
(#6)
MAJ/MIN/
WRN
3
ON test trunk <grp>/<mbr> l r
3
1793 (h) test board PCSS long
2305(i) 50944 DS1 Tie Trunk
Seizure Test (#136)
MIN/MAJ
3
OFF
Continued on next page