Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-532DIOD-DS1 (DS1 DIOD Trunk)
3
This test cannot be run on a trunk in any of the following conditions:
The trunk direction is administered as an incoming only trunk.
The trunk has been seized by a normal trunk call.
The trunk is administered with maintenance test disabled.
Table 3-225. TEST #314 DS1 CO Dial Tone Seizure Test
Error
Code
Te st
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may
be in use on a valid call. Use the status trunk command to determine
when the port is available for testing.
1004 ABORT The port has been seized by a user for a valid call. Use the status trunk
command to determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT Test failed due to incompatible configuration administered in trunk group
form.
1. Look at the trunk group administration form and see whether the trunk
is incoming only, port 24 on a DS1 Interface with common control
channel signaling, or an automatic CO type such as FX. Under any of
these conditions this is a normal abort.
1018 ABORT Test has been disabled via administration.
1. Verify that the
Maintenance Tests field on the Trunk Group Form
is set to n. To enable the test, issue the change trunk-group x
command where ‘‘x’’ equals the number of the trunk group to be
tested. Then change the entry in the
Maintenance Tests field on
the form to y.
2. Repeat the test.
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for UDS1-BD errors in the Hardware Error Log. If present, refer to
the UDS1-BD (DS1/UDS1 Trunk Circuit Pack) Maintenance
documentation.
2. Retry the command.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page