DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-640EMG-XFER
3
EMG-XFER
Emergency Transfer (SCC Cabinets)
The system provides the ability to cut designated analog phones through to CO
trunks if the switch cannot provide even minimal phone service. This ability is
known as Emergency Transfer. The EMG-XFER MO tracks the control of
Emergency Transfer. There is one EMG-XFER MO for the port network.
Emergency Transfer can be controlled by the system or can be manually
controlled via the Emergency Transfer switch located on the Processor circuit
pack. A manual ON position (up) generates a Major alarm. A manual OFF
position (down) generates a Warning alarm. Unless a technician is currently
working on the system, the switch should be left in the auto position.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. Where P is an appropriate port network number determined via the PORT field from the
Alarm or Error Log.
Full Name of MO
EMG-XFER MAJOR test environment P Emergency Transfer
EMG-XFER WARNING test environment P Emergency Transfer
Table 3-263. Emergency Transfer Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test environment P sh r 1
1 Any Emergency Transfer
Query (#124)
MAJOR ON test environment P r 3
257 0 Emergency Transfer
Query (#124)
WARNING ON test environment P r 3