DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-17ADX16D-B (16 Port AUDIX Circuit Pack)
3
ADX16D-B (16 Port AUDIX Circuit
Pack)
The ADX16D-BD maintenance object represents a TN566/TN2169 DEFINITY
AUDIX circuit pack combination operating in 16 port mode digital (DP). For
circuit-pack-level problems, see “XXX-BD (Common Port Circuit Pack)”.
Port-level maintenance is covered by ADX16D-PT.
DEFINITY AUDIX consists of 2 circuit packs that occupy 4 slots on a port carrier.
The tests described in this manual apply only to switch-side maintenance which
tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy of its own that is described in
DEFINITY AUDIX System Maintenance
, 585-300-110.
MO Name (in
Alarm Log)
Alarm
Level Initial Command To Run
1
1. Where P is the port network number (1 for PPN); C is the carrier designation (for
example, A, B, or C); SS is the address of the slot in the carrier where the circuit pack is
located (for example, 01, 02, ..., etc.).
Full Name of MO
ADX16D-B MINOR test board PCSS sh AUDIX Circuit Pack
ADX16D-B WARNING test board PCSS sh AUDIX Circuit Pack