DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1196UDS1-BD (UDS1 Interface Circuit Pack)
3
1300 FAIL The CSU Module/T1 Sync Splitter or the E1 Sync Splitter is missing.
The CSU Module/T1 Sync Splitter is missing: The
Near-End CSU Type
field on
the
add ds1
form has been administered as
integrated
but the 120A1 CSU
Moduler or the 401A T1 Sync Spliltter is not physically connected to the TN464F
board on the back of the port carrier.
1. If using the 120A1 CSU Module or the 401A T1 Sync Spliltter, plug the CSU
Module/T1 Sync Splitter into the TN464F circuit pack’s connector on the I/O
connector panel on back of the carrier. Otherwise, change the
Near-End
CSU Type
field using the
change ds1
form to
other
.
2. Run the test again.
The E1 Sync Splitter is missing: The
E1 Sync-Splitter?
field on the
add ds1
form
has been administered as
y
but the 402A or 403A E1 Sync Splitter is not
physically connected to the TN464F board on the back of the port carrier.
1. If using the 402A or 403A E1 Synchronization Splitter, plug the E1SS into
the TN464F circuit pack’s connector on the I/O connector panel on back of
the carrier. Otherwise, change the
E1 Sync-Splitter?
field using the
change
ds1
form to
n
.
2. Run the test again.
1301 FAIL The 120A1 CSU Module or the 401A T1 Sync Spliltter, or the 402A or 403A E1
Synchronization Splitter is not expected.
The 120A1 CSU Module or the 401A T1 Sync Spliltter is not expected: The
120A1 CSU Module/T1 Sync Splitter is physically connected to the TN464F
board on the back of the port carrier but the
Near-End CSU Type
field on the
add ds1
form has not been administered as
integrated
.
1. If the 120A1 CSU Module/T1 Sync Splitter is to be used, use the
change
ds1
command to change the
Near-End CSU Type
field to
integrated
.
Otherwise, physically remove the 120A1 CSU Module/T1 Sync Splitter from
the back of the port carrier.
2. Run the test again.
The 402A or 403A E1 Synchronization Splitter is not expected: The 402A or
403A E1 Synchronization Splitter is physically connected to the TN464F board
on the back of the port carrier but the
E1 Sync-Splitter?
field on the
add ds1
form has not been administered as
y
.
1. If the 402A or 403A E1 Synchronization Splitter is to be used, use the
change ds1
command to change the
E1 Sync-Splitter?
field to
y
. Otherwise,
physically remove the 402A or 403A E1 Synchronization Splitter from the
back of the port carrier.
2. Run the test again.
Table 3-519. TEST #138 Loss of Signal Alarm Inquiry Test — Continued