Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-122list measurements ds-1
2
Output
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
list
measurements
log
summary
ds1_location
print
schedule
Detailed report generated
Summary report generated
The physical location of a DS1
circuit pack entered as
cabinet-carrier-slot.
Report sent to printer.
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
1
Examples:
list measurements ds1 log 2a18
list measurements ds1 summary
2a18 print
list measurements ds1 summary
2a18 schedule
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
cust
rcust
browse
nms
bcms
none none
list measurements ds1 summary 2a19 SPE A
Switch Name: Date: 1:25 pm THU APR 16, 1992
DS-1 Link Performance Measurements Summary Report
Counted Since: 1:20 pm THU APR 16, 1992
Number of Seconds Elapsed Into Current 15-min Interval: 323
Total of Valid 15-min Intervals in Past 24-hr Period: 0
Total of Current
Worst_15-Min_Interval 24-hr 15-Min Interval
Category Date Time Count Count Count
Errored Seconds 4/16 13:20 0 0 4
Bursty Err Secs 4/16 13:20 0 0 4
Severely Err Secs 4/16 13:20 0 0 0
Failed Seconds 4/16 13:20 0 0 0
Command successfully completed