DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1133TONE-BD (Tone-Clock Circuit Pack)
3
3. If error 2305 or 3848 persists, all clock signals from the indicated
board were lost. If the reported Tone-Clock circuit pack is in a Port
Network with duplicated Tone-Clocks, the problem may lie with the
circuit pack responsible for selecting the active Tone-Clock circuit
pack (the
t/c selector
).
For a PPN, the t/c selector is the DUPINT circuit pack on
carrier A.
For an EPN, the t/c selector is the active EXP-INTF circuit
pack that is connected to the PPN. This is EXP-INTF 2A01 or
2B02 for EPN1 and 3A01 or 3B02 for EPN2.
The t/c selector circuit pack of interest is the one which was active
at the time the error was logged. This is the currently active t/c
selector unless there has been an SPE interchange for PPN
problem, or an EXP-INTF link switch for EPN problem, In order to
determine whether an interchange has occurred since the
TONE-BD error, examine the
display initcauses
log for SPE
interchanges, and EXP-LNK entries in the hardware error log for
expansion link interchanges.
If the t/c selector circuit pack was not replaced as part of the
previous step, replace it now.
4. If the error has not been corrected at this point, there is a problem
with the TDM Bus within the Port Network containing the reported
Tone-Clock circuit pack. This may include TDM Bus intercarrier
cables, Bus terminators, bent pins on the backplane, and errors on
any circuit pack plugged into the same Port Network. Refer to the
TDM-BUS section.
5. If the problem persists, follow normal escalation procedures.
l. Error Type 2561
This error indicates that a Tone-Clock circuit pack, with
a different circuit pack code as required for this system, has been inserted
in the port slot as shown in the Hardware Error Log. To resolve this error,
refer to the ‘‘How to Replace a Tone-Clock Circuit Pack’’
section for an
appropriate circuit pack code and replace the Tone-Clock circuit pack
according to the procedures indicated for this system. The meanings of
the aux data values are as follows: