DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-391CO-TRK (CO Trunk)
3
3. CO On-Hook first (Disconnect): Open circuit on Tip, no loop
current.
a. PBX Response: Open Tip-Ring loop
b. B. Incoming Call
1. CO Off-Hook (Seizure): CO applies ground on Tip, CO applies
ringing voltage
a. PBX Response: Detect ringing, ring destination
2. PBX Off-Hook (Answer Message): Close loop
a. CO Response: Trip ringing, provide loop current
3. PBX On-Hook first (Drop Message): Open the Tip-Ring Loop, no
loop current
a. CO Response: Open circuit on Tip
4. CO On-Hook first (Disconnect): Open circuit on Tip, no loop current
Hardware Error Log Entries and Test to Clear
Valu es
Table 3-171. CO Trunk Error Log Entries
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) 57347 None
15 (b) any Port Audit Update
Test (#36)
18 0 busyout trunk
<grp>/<mbr>
WARNING OFF release trunk
<grp>/<mbr>
130(c) None WARNING ON test trunk <grp>/<mbr>
257 (a) 50176 None
513 (a) 57364 None MAJ/MIN/
WRN
2
ON
769 (a) 57392 None MAJ/MIN/
WRN
2
OFF
1025 (e) Any Demand Diagnostic
Test (#3)
MAJ/MIN/
WRN
2
OFF test port PCSS sh r 2
1281 (e) Any Demand Diagnostic
Test (#3)
MAJ/MIN/
WRN
2
ON test port PCSS sh r 3
Continued on next page