Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-222status audits
2
Audit information displays with one line of data displayed audit that has detected
an error or aborted. Audits that did not detect any errors or aborted do not
display. The output sorts in descending order, based on the sum of the values in
the
# Cycles Fixed Data
,
# Cycles Could Not Fix Data
, and
# Cycles Audit Aborted
fields.
Field descriptions
Start Date
Date and time that interval begins. “cumulative” = date and time of
the last reboot or execution of the “clear audits cumulative”
command.
“peak-hour” = date and time of the beginning of the peak hour
since the last reboot or execution of a “clear audits cumulative” or
“clear audits peak-hour” command.
# of Audit Cycles
Completed
Number of audit cycles completed in the specified interval
(0 – 999999). Asterisks indicate numbers that exceed 999999. The
switch executes audits in a set order. After all audits execute, the
switch restarts the sequence.
NOTE:
Since this field shows the number of completed audit cycles,
it is possible that individual audit values, can be larger than
the values described below (if the switch is partially through
another audit cycle). Audit Cycles numbers do not apply to
these audits that execute as part of scheduled maintenance.
Audit Name
Audit’s name that detected an error or aborted. A few audits do not
run in the normal audit sequence. Instead, they execute as part of
scheduled maintenance and are marked with “(SCH)” following the
audit name.
# Cycles Fixed
Data
Number of times that the audit ran, in the specified interval, and
found a fixable problem. (0–65534) Asterisks are used form
numbers that exceed 65534.
# Cycles Could
Not Fix Data
Number of times that the audit ran, in the specified interval, and
found an unfixable problem. The audited switch data is
inconsistent when this happens. (0–65534) Asterisks are used for
numbers that exceed 65534.
# Cycles Audit
Aborted
Number of times that the audit ran, in the specified interval, and
aborted due to an internal error. (0–65534) Asterisks are for
numbers that exceed 65534.
First Error
Date and time that the audit first detected fixed data, could not fix
data or audit aborted problems since the last
clear audits
cumulative
command. Example: 03/27/14:31 for 2:31 pm, March
27th. This field appears with the
status audits cumulative
display.