DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-872PE-BCHL (PRI Endpoint Port)
3
Signaling
link has
been down
for over 90
seconds?
X
Warn Alarm
See ISDN-SGRP,
ISDN-LNK, PKT-INT
and/or SYS-LINK and
follow repair
procedures.
Is far-end terminal
adapter currently
restarting?
Repeated
failure of
far-end to
respond to
messaging?
X
Warn Alarm
Periodically
Maintenance will try to
resend messages. To
speed process, run
system
technician-demanded
test test port
PCSSpp (Test #256).
Far-end port
busied out
(OOS/FE).
Far-end port
being tested
( MTC E/FE) .
X
Warn Alarm
X
Warn Alarm
Check status of
far-end terminal
adapter.
Table 3-375. PRI Endpoint Port Service States — Continued
Possible
Problem
Source
O/S-NE
O/S-FE
O/S- FE Pend- ins
maint-NE
maint- FE
maint-FE Pend- ins
INS
Possible Recovery
Route
Continued on next page