DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-625DTMR-PT [Dual Tone Multifrequency Port (TTR)]
3
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
Tone
Detection Verification Test,
for example, you may also clear errors generated from
other tests in the testing sequence.
Tone Detection Verification Test (#42)
This test verifies the "touch-tone digits detection" capability of the DTMR port is
functioning properly.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
Tone Detection Verification Test (#42) X X ND
Tone Detector Audit/Update Test (#43) X X ND
Table 3-257. TEST #42 Tone Detection Verification Test
Error
Code
Te s t
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources needed for this test
or there was an internal system error.
1 ABORT The system could not allocate all the resources needed to test the DTMR
port.
1001 ABORT The system was unable to put the DTMR port in the appropriate mode to
test it.
1002 ABORT The system could not allocate time slots for the test connection. This could
happen when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM Bus via the test tdm [a|b] command. Refer to
the TDM-BUS (TDM Bus) Maintenance documentation for details.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page