Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-286BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)
3
Electronic Power Feed Inquiry (#622)
This test queries the BRI-LINE circuit pack for the status of the Electronic Power
Feed (EPF) supplied to a BRI endpoint or an ASAI or Lucent adjunct. If the EPF is
on and no overcurrent condition exists, this test passes. All other states are not
normal and indicate a problem with the endpoint or adjunct, the wiring to the
endpoint or adjunct, or the BRI-LINE circuit pack. This test is not run on the
TN2208 circuit pack or the TN2198 and will always return a pass for a TN2198.
The TN2208 has no power feeds.
Table 3-123. TEST #622 Electronic Power Feed Inquiry
Error
Code
Test
Result Description/ Recommendation
1005 ABORT This test is not valid for this port type. Ports on the TN2208 cannot run
this test because this board does not have an electronic power feed.
2000 ABORT Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit
pack via the busyout board PCSS and reset board PCSS
commands.
2. If the test aborts again, replace the circuit pack.
2012 ABORT Internal system error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 FAIL The BRI-LINE circuit pack reports that it has detected an overcurrent
condition and has turned off the EPF.
1. As necessary, check and repair the wiring between the circuit pack
and the endpoint or adjunct. Check the endpoints and replace one
or both sets if the sets are drawing too much current. Execute the
test port PCSSpp command and review the results of the EPF
Inquiry Test to verify the repair. If this test is still failing, proceed to
Step 2.
2. Execute the test port PCSSpp command, and review the results of
the Level 1 Status Inquiry Test. If this test is also failing, then follow
the repair procedure for the Level 1 Status Inquiry Test.
2000 ABORT Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit
pack via the busyout board PCSS and reset board PCSS
commands.
2. If the test aborts again, replace the circuit pack.
PASS The Electronic Power Feed Inquiry Test reports that the EPF is on.
Continued on next page