Maintenance Objects
3-398CO-TRK (CO Trunk)
3
Table 3-173. TEST #0 Dial Tone Test
Error
Code
Te st
Result Description/ Recommendation
ABORT Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the command display port PCSSpp to
determine the trunk group/member number of the port. Use the status
trunk command to determine the service state of the port. If the service
state indicates that the port is in use, then the port is unavailable for certain
tests. You must wait until the port is idle before retesting.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1001 ABORT System resources required to run this test were not available. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
1004 ABORT The port was seized by a user for a valid call. Use the display port
PCSSpp command to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the
port. If the service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1005 ABORT Trunk has been administered as incoming-only; dial tone can only be
obtained on outgoing trunks. This is a normal condition.
1018 ABORT Test has been disabled via administration.
1. Verify that the
Maintenance Tests? field on the Trunk Group
Form is set to n. To enable the test, issue the change trunk-group x
command where "x" equals the number of the trunk group to be tested.
Then change the entry in the
Maintenance Tests? field on the
form to y.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page