Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1127TIE-TRK (Tie Trunk)
3
1947 ABORT Noise with tone self check failed.
1. Test the TN798 circuit pack.
2000 ABORT The test timed out while waiting for a response from the TN798 circuit
pack.
1. Retry the command at 1-minute intervals for a maximum of 5 retries.
2012 ABORT An internal software error occurred.
1. Retry the command at 1-minute intervals for a maximum of 5 retries.
2053 ABORT The test call could not be established, but no information on why is
available.
1. Retry the command at 1-minute intervals for a maximum of 5 retries.
2056 ABORT An error occurred while trying to obtain results from the TN771 circuit
pack.
1. Test the TN798 circuit pack.
FAIL Measured transmission performance was in the unacceptable range as
administered on the trunk group form. Retrieve a measurement report via
the list testcalls command. Make sure that ATMS thresholds are set
properly on page 4 of the Trunk Group form. Besides the facility, test
failures can be caused by faulty test lines or switch paths. If the
measurements point to a facility problem, report the results to the trunk
vendor.
8000 FAIL Measured transmission performance was in the marginal range as
administered on the trunk group form. This generally means that the trunk
is usable but has an undesirable amount of noise or loss. If the user does
not report unacceptable effects, it may not be necessary to take any
action. Retrieve a measurement report via the list testcalls command.
Make sure that ATMS thresholds are set properly on page 4 of the Trunk
Group form.
Table 3-496. TEST #844-848 Transmission Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page