DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-741ISDN-TRK (DS1 ISDN Trunk)
3
Error Log Entries and Test to Clear Values
Notes:
a. These error types indicate a disagreement between this switch and the
switch at the other end of the trunk connection with regard to the ISDN
call
state of the DS1 ISDN Trunk. This switch will automatically try to recover by
clearing the call, (that is, the call will be torn down). You can use the
status trunk <trunk_group/trunk_member>
command to determine the
state of the trunk.
Table 3-310. DS1 ISDN Trunk Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1 (a) Any None test port PCSSpp sh r 1
15 (b) Any Audit and Update
Test (#36)
18 0 busyout trunk
<grp>/<mbr>
release trunk
<grp>/<mbr>
129 (c) None WARNING OFF test port PCSSpp
130 (d) None WARNING ON test port PCSSpp
257 (e) Any None test port PCSSpp
513 (f) Any None WARNING OFF test port PCSSpp
769 (e) Any None test port PCSSpp
1281 Any Conference Circuit
Test (#7)
MIN/ WRN
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command. If the Minor alarm is not downgraded by the set options values, then the
Minor alarm will be upgraded to a Major alarm if 75 percent of the trunks in this trunk group are
alarmed.
ON test port PCSSpp l r 4
1537 Any NPE Crosstalk Test
(#6)
MIN/WRN
2
ON test port PCSSpp l r 3
1793 (g) Any None test port PCSSpp
3073 (h) Any Service State Audit
(#256)
test port PCSSpp
3585 (i) Any None None
3841 (j) Any None None