Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1092TIE-DS1 (DS1 Tie Trunk)
3
Notes:
a. Error Type 1
The DS1 Interface circuit pack detects a hardware error on
the DS1 tie trunk. This error can be caused by incompatible translations.
Make sure the parameters administered on the DS1 circuit pack form
match those administered on the far-end switch.
The Aux Data field indicates the following hardware error types:
If all administration errors between the switch and the far-end match, and
these errors continue to recur, follow normal escalation procedures.
b. Error Type 15
This is a software audit error that does not indicate any
hardware malfunction. Run Short Test Sequence and investigate
associated errors (if any).
c. Error Type 18
The DS1 tie trunk has been busied out by a
busyout trunk
grp/mbr command. No calls can be made on this trunk except for the
Facility Access Test Call.
d. Error Type 130
This error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes. To clear the error,
reinsert or replace the circuit pack.
e. Error Type 257
The DS1 Interface circuit pack detects a hardware error
on the DS1 tie trunk. The trunk cannot communicate with the far end
because it is unable to interpret digits sent from the far-end switch. The
Aux Data field indicates the following:
Check with the far-end switch or operating company for proper trunk
connection.
f. Error Type 513
DS1 Interface circuit pack detects a hardware error on
the DS1 tie trunk. The trunk is in-service/active and waiting for an
‘‘on-hook’’ from the far-end switch. No calls can be routed over the trunk
while it is in this state. Aux Data 57392 indicates no external release on
PBX disconnect. Check with the far-end switch or operating company for
proper trunk connection.
g. Error Type 769—The DS1 Interface circuit pack detects a hardware error
on the DS1 tie trunk. This error usually occurs after one or more
occurrences of error type 513. The trunk has received the belated
57476 On-hook before wink
57477 On-hook before ready to receive digits
57485 Wink too short for valid signal
57487 The timer expired while waiting for an off-hook
signal from the far end as a response at end of
digits dialing. Check the far-end switch for related
problems.
57473 The rotary dial rate is below 8 pulses per second.
57474 The rotary dial rate is above 12 pulses per second.