Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-27ADX16A-PT (AUDIX Analog Line/Control Link)
3
ADX16A-PT (AUDIX Analog
Line/Control Link)
!
CAUTION:
Never do any of the following without first shutting down AUDIX. Follow
instructions in the ‘‘Power Down AUDIX System’’
section in Chapter 1,
‘‘Maintenance for csi systems’’.
The ADX16A-PT maintenance object represents a port on a TN566/TN2169
DEFINITY AUDIX circuit pack that is operating in control-link (CL) mode. For
circuit-pack-level problems (ADX16A-BD or ANL-16-BD), see “XXX-BD (Common
Port Circuit Pack)”. For port-level problems with AUDIX operating in digital-port
mode, see ADXDP-PT/ADX8D-PT.
The tests described in this section apply only to switch-side maintenance which
tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy that is described in
DEFINITY
AUDIX System Maintenance
, 585-300-110.
AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction
Board (MFB) and the TN2169 Alarm Board (ALB). Because of its size this
combination occupies 5 slots, but only 1 slot is functional as far as the switch is
concerned. The other 4 slots are seen by the switch as ‘‘AUDIX-reserved’’ slots.
In CL mode the TN566 pack supports up to 16 voice ports. When a call to a
station with an AUDIX login is not answered, AUDIX answers the call using one of
the available voice ports.
Unlike other AUDIX systems, DEFINITY AUDIX is not an adjunct.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command To
Run
1
1. Where P is the port network number (1 for PPN); C is the carrier designation (for example, A, B,
or C); SS is the address of the slot in the carrier where the circuit pack is located (for example, 01,
02, ..., etc.); and pp is the 2-digit port number (for example, 01).
Full Name of MO
ADXCL-PT or
ADX16A-PT
MINOR test port PCSSpp l AUDIX Analog Line/ Control Link
ADXCL-PT or
ADX16A-PT
WARNING test port PCSSpp sh AUDIX Analog Line/ Control Link