Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-81display system-parameters maintenance
2
Field descriptions
Defaults for data entry fields are listed in parentheses.
Product
Identification
10-digit number (starting with 1) that identifies the switch to an
Operations Support System (OSS), for example, INADS.
First OSS Telephone
Number
First telephone number that the switch dials to report alarms;
must be obtained from the National Customer Support Center
(NCSC) or the TSC. (
#
and
*
are not allowed in the telephone
number.)
Abbrev Alarm Report
Enables the Abbreviated Alarm Report feature for the first OSS.
(yes)
Second OSS Telephone
Number
Second telephone number that the switch dials to report alarms;
must be obtained from the National Customer Support Center
(NCSC) or the TSC. (
#
and
*
are not allowed in the telephone
number.)
Abbrev Alarm Report
Enables the Abbreviated Alarm Report feature for the second
OSS. (no)
Alarm Origination to
OSS Numbers
One of four options for alarm origination (neither):
If
both
, all Major and Minor alarms result in an automatic
call to both OSS telephone numbers. Both OSS telephone
numbers must be administered.
If
first-only
, all Major and Minor alarms result in an
automatic call to the first OSS number only. The switch does
not call the second OSS telephone number even if the
number is administered. The first OSS telephone number
must be administered
If
neither
, alarm origination does not take place. Warning
alarms are not reported to either numbers.
If
second-as-backup
, all Major and Minor alarms result in
an automatic call to the first OSS telephone number. If
calling the first OSS telephone number fails four attempts,
the switch starts to call the second OSS telephone number
as a backup until calling the first OSS telephone number
becomes successful. Both OSS telephone numbers must be
administered.
Before Release 5, the name of this field is
Alarm
Origination Activated
. If Alarm Origination is deactivated,
both Cleared Alarm Notification and Restart Notification are
disabled, even though they may still be activated in the
administration.