DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-310status trunk
2
Group only
The following example shows the output from the
status trunk 78
(trunk group
only) command.
Field descriptions
Service State
Trunk service state:
in-service/active, in-service/idle, out-of-service-NE,
out-of-service-FE, maint-NE/active, maint-FE/active, maint-NE/idle,
and maint-FE/idle.
NE (Near End; switch) and FE (Far End; PRI terminal adapter or any
device that terminates the D-channel signaling) refer to which
“end” of the B-channel has placed the facility in the current state.
Maintenance
Busy
Whether any maintenance testing is being performed
CA-TSC State
State of the temporary signaling connection (used to pass call
information over PRI signaling links)
Member
Trunk group number/group member number (1-99/1-99).
Port
Port location (cabinet-carrier-slot-circuit)
Service State
Trunk service state:
in-service/active, in-service/idle, out-of-service-NE, out-of-service-FE,
maint-NE/active, maint-FE/active, maint-NE/idle, and maint-FE/idle.
NE (Near End; switch) and FE (Far End; PRI terminal adapter or any
device that terminates the D-channel signaling) refer to which “end”
of the B-channel has placed the facility in the current state.
Mtce Busy
Whether any maintenance testing is being performed
Connected
Ports
Port locations (cabinet-carrier-slot-circuit) connected to the trunk
status trunk 78
TRUNK GROUP STATUS
Member Port Service State Mtce Connected Ports
Busy
078/001 01C1505 in-service/idle no
078/002 01C1506 in-service/idle no