DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-991S-SYN-PT (Speech Synthesis Port)
3
Speech Synthesis PSS Handshake Test (#168)
This test verifies control functionality between the on-board microprocessor and
PSS controller. A failure occurs if either of the following events occur:
The on-board microprocessor times out while waiting for the PSS controller
to respond.
An invalid command is received by the on-board microprocessor from the
PSS controller.
This type of failure affects all four ports on the Speech Synthesis circuit pack,
resulting in errors or alarms on each port.
Table 3-438. TEST #167 Speech Synthesis SSD Inquiry Test
Error
Code
Te s t
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call and therefore unavailable for certain tests. You must wait
until the port is idle (yellow LED if off) before retesting.
1. If the port is idle, retry the command at 1-minute intervals a maximum of 5
times.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any FAIL The SSD is insane.
1. Replace the circuit pack.
PASS The SSD is sane. User-reported troubles should be investigated using other
tests and verifying other ports on this circuit pack are working correctly.
Continued on next page