DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-290BRI-SET, ASAI-ADJ, BRI-DAT
3
BRI-SET, ASAI-ADJ, BRI-DAT
The TN2208 ESAI MFB provides DEFINITY with an Ethernet interface to
Adjunct-Switch Application Interface (ASAI) and Lucent adjuncts (for example,
CONVERSANT
®
Voice System). This circuit pack contains 8 ports of line circuit
interface, each of which operates with two B-channels (referred to as B1 and B2
throughout this section) and one D-channel as specified in the Lucent ISDN-BRI
Specification. In this context, the term ‘‘ISDN-BRI port’’ is used to refer
collectively to ports on the TN2208 MFB circuit pack which is connected to ASAI
MO Name (in
Alarm Log) Alarm Level Initial Command to Run
1
1. Where P is the port network number (1 for PPN); C is the carrier designation (A, B, or C); SS is
the address of the slot in the carrier where the circuit pack is located (01, 02, ..., etc.); and pp
is the 2-digit port number (for example, 01). The alternate name field contains the extension of
the endpoint. This field is used to distinguish between endpoints on the same port.
Full Name of MO
BRI-SET WARNING
2
2. The alarm level for ASAI and Lucent adjuncts may be administered using the set options
command. The alarm level can be set independently for Off-Board and On-Board alarms to
WARNING, MINOR, or MAJOR for all ASAI and Lucent adjuncts in the system.
test station extension l,
test data-module extension
ISDN-BRI Set
ASAI-ADJ MAJOR
2
test station extension ASAI-Adjunct
ASAI-ADJ MAJOR
2
test data-module extension ASAI-Adjunct
ASAI-ADJ WARNING
3
3. Alarming for an ASAI and Lucent adjuncts is disabled if the adjunct asks the switch to suspend
maintenance. When this occurs, an error and a WARNING alarm are logged against the
endpoint. Busying out and releasing the ASAI station or ADJLK station will clear the alarm.
test data-module extension ASAI-Adjunct
ATT-ADJ MAJOR
2
test station extension Lucent-Adjunct
ATT-ADJ MAJOR
2
test station extension Lucent-Adjunct
ATT-ADJ WARNING
3
test station extension Lucent-Adjunct
LGATE-AJ MAJOR
2
test station extension Ethernet ASAI-Adjunct
LGATE-AJ MAJOR
2
test station extension Ethernet ASAI-Adjunct
LGATE-AJ WARNING
3
test station extension Ethernet ASAI-Adjunct
ATTE-AJ MAJOR
2
test station extension Ethernet
Lucent-Adjunct
ATTE-AJ MAJOR
2
test station extension Ethernet
Lucent-Adjunct
ATTE-AJ WARNING
3
test station extension Ethernet
Lucent-Adjunct
BRI-DAT test data-module