Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-129ATM-BCH (ATM B-Channel Trunk)
3
b. Error Type 129: the far-end switch changed its ISDN service state to either
out-of-service or maintenance. This may be a temporary condition
because the far-end is testing that trunk or a hardware problem with the
trunk. Outgoing calls may not be allowed over that trunk.
1. Investigate the trunk status (
status trunk
grp#/mbr#
).
c. Error Type 130: the circuit pack has been removed or has been insane for
more than 11 minutes.
1. Reinsert or replace the circuit pack to clear the error.
d. Error Type 257: SETUP received for a B-channel that is in an invalid
service state. Service states may be incompatible at the two ends of the
trunk. A normal call was received while the B-channel was MTC/FE,
MTC/NE, OOS/FE, or OOS/NE or a test call was received while the
B-channel was OOS/FE or OOS/NE.
e. Error Type 513: RELease COMplete message received with cause value
82 (nonexistent channel). The B-channel may not be administered at the
far end. The trunk has been placed in the OOS/FE state.
f. Error Type 769: inconsistent SERVice or SERVice ACKnowledge
message. Possible causes:
SERVice or SERVice ACKnowledge message received containing a
change status that is more available than the previously-transmitted
SERVice message.
Unsolicited SERVice ACKnowledge message received containing a
change status that does not match the current B-channel state.
ISDN-PRI service-state negotiation rules have been violated and may
indicate that a pending service-state audit is failing. The system
cancels the maintenance timer
increments the Service State Audit counter
attempts a Service State Audit
When running the Short Test Sequence, pay close attention to the results
of the Service State Audit Test (#256).
g. Error Type 1793: TN230x circuit pack has failed. The maintenance system
places the trunk in the OOS/NE state
sends a SERvice message to the far-end (if possible) containing a
change status of OOS for the B-channel
returns the trunk to service when the ATM trunk circuit pack reports
the failure cleared
h. Error Type 3073: Service State Audit attempt failed (see Test #256). Calls
can be received but not placed until the test passes and the trunk state
returns to In-Service.
1. Check the trunk status (
status trunk
grp#/mbr#
).