DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-753ISDN-TRK (DS1 ISDN Trunk)
3
There are two methods available to place an outgoing ISDN-PRI test call.
In the first method, the test call connection is established over the TDM Bus of
the transmit and receive sides of the ISDN-PRI trunk to a data channel. This
method is selected when no Maintenance/Test circuit pack resides in the system.
In the second method, the test call connection is established over the TDM Bus
of the transmit and receive sides of the ISDN-PRI trunk to a digital trunk testing
port on the Maintenance/Test circuit pack. The Maintenance/Test Digital Port
generates a pseudo bit stream. A pictorial description of the outgoing ISDN-PRI
test call connectivity is contained in Figure 3-28
.
Figure 3-28. ISDN-PRI Outgoing Test Call
Synchronous Commands
You can demand a synchronous outgoing test call by using the following
maintenance commands:
test trunk trunk-group-no/member-no long [repeat number]
test board board-location long [repeat number]
test port port-location long [repeat number]
Whenever a circuit translates to an ISDN-PRI trunk during a Long Test Sequence,
an outgoing test call is invoked. If the B-channel is unrestricted (B8ZS or HDB3)
the default duration of the test call is 8.6 seconds. Otherwise, if the B-channel is
PI (TN765)
or
PACCON
(TN778)
NETCON SPE
D-channel Setup
B-channel
B-channel
TDM BUS
M/T
TN7771B
DS1/UDS1