DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-576DS1-BD (DS1 Interface Circuit Pack)
3
Red Alarm Inquiry Test (#140)
DS1 Interface circuit pack raises a Red alarm when the framing pattern of the
incoming DS1 bit stream has been lost. The Red Alarm Inquiry Test checks the
framing status of a DS1 Interface circuit pack. DS1 Interface circuit pack takes 3
seconds to recognize and report a Red alarm and 10 seconds to recognize and
report the resolution of a Red alarm.
When the DS1 Interface circuit pack detects a Red alarm, the circuit pack will
transmit a Yellow alarm to the remote DS1 endpoint and send a RED ALARM
message to the maintenance software. After the Red alarm is confirmed, the
maintenance software places all trunks of the circuit pack into the out-of-service
state. The inquiry test will be run every 10 minutes until the Red alarm is cleared.
When the Red alarm is cleared, the DS1 Interface circuit pack will stop
transmitting the Yellow alarm to the remote DS1 endpoint. The maintenance
software restores all trunks of the DS1 Interface circuit pack to the service state
before the Red alarm occurs.
Loss of Multiframe Alarm: If the DS1 Interface circuit pack is administered using
DMI-BOS signaling, the DS1 Interface circuit pack raises a Loss of Multiframe
Alarm (LMA) when it cannot interpret the incoming signaling bits to synchronize
to the multiframe pattern received in the 24th channel. Once DS1 Interface circuit
pack detects an LMA, the circuit pack will transmit a Remote Multiframe Alarm
(RMA) to the remote DS1 endpoint. Maintenance software handles both Red
alarm and LMA alarm(s) using the same mechanism.