DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-77display system-parameters duplication
2
Field descriptions
display system-parameters duplication
This command displays the status (enabled or disabled) of Switch Processing
Element (SPE) and Port Network Connectivity (PNC) duplication. The following
must be duplicated:
Each switch node record and every switch node with its duplicate (cabinet
administration is a prerequisite)
Every fiber link containing either an expansion interface circuit pack as an
endpoint, or a DS1-C (fiber link administration is a prerequisite; circuit
pack administration then follows duplication administration)
Stratum:
Synchronization stratum that is used (3 or 4)
Primary:
First choice system synchronization source (blank = no
synchronization); valid only if stratum 4 synchronization specified
Secondary:
Second choice system synchronization source (blank = no
synchronization); valid only if stratum 4 synchronization specified
Location:
Circuit pack location (cabinet-carrier-slot) of all administered DS1 circuit
packs are listed here.
Name:
User-defined name administered for the DS1 circuit pack. Blank means
no user-defined name administered.
Slip:
If the DS1 circuit pack has slip alarm, field shows
y
; otherwise,
n
.
Port
Network:
Stratum 3 only; specifies the port network supplying synchronization
through the tone clock circuit pack.
display synchronization Page 1 of 2
SYNCHRONIZATION SOURCE (Synchronization Plan circuit pack location)
Stratum: 4
Primary: Secondary:
DS1 CIRCUIT PACKS
Location Name Slip Location Name Slip
01C10 D92D1 ds1 1c10 n
01C11 D92D1 ds1 1c11 n
NOTE: DS1 and BRI Trunk sources result in stratum 4, type II synchronization